Is your EZABL working well? (M48 Test)

Support Portal  »  Products  »  Viewing Article

  Print

About the M48 Test

One of the first things you should do if you are having issues is check how well it’s working by using the M48 command to test it.

If your M48 test results in a value of 0.01 or lower for the standard deviation then the probe is working and something else on the printer is causing issues with the resulting 1st layer. Common issues are: Gantry Being Unlevel, Extrusion Issues with hotend and/or extruder, or mechanical issues.

In our latest firmware M48 is enabled by default for ALL machines that we support. Please update to the latest one before contacting support as it addresses issues present in older firmware releases.

Running the Test from your LCD

On the latest Unified 2 firmware (and some versions of Unified 1) we have the M48 test built into the LCD. This is available for most printers that use the standard Marlin LCD interface. If you have a touch/color LCD (Like the Ender 3 V2) you will need to run the probe test manually with the directions below.

With your printer at temperature (on the hotend and bed) and your bed clear go to your LCD and press the knob. Then go to Motion and select M48 Probe Test

The printer will home XYZ and then start the test. You will see “M48 Point X/10” on the LCD. It will take 10 probe readings and then show you a number on the LCD. This number should be 0.01 or lower.

Result 0.01 or lower? Your probe is setup and working correctly.

Result higher than 0.01? You need to run back through the installation guide. Make sure the probe is mounted and calibrated per the EZABL installation guide directions.

Manually Running the Test

Use commands like this to run 10 probes and get the measurements:

M48 P10 X100 Y100 V2

The output will look like this:

M48 Z-Probe Repeatability Test Finished!

Mean: 3.450000 Min: 3.442 Max: 3.452 Range: 0.010Standard Deviation: 0.004330

This shows the absolute maximum and minimum measurements the sensor took, the mean (average) of all the measurements, the range between the maximum and minimum, and the standard deviation.

The standard deviation is interesting because it tells us that 68% of all the measurements were within 0.00433mm (one standard deviation) of either side of the mean, and 95% of the measurements were within 0.00866 (two standard deviations) of the mean.

A good probe should consistently give a range in the hundredths of mm, e.g. 0.05mm. An exceptionally good probe will have a range in the thousandths. EZABL™ probes typically test UNDER 0.02mm and the EZABL™ Pro probes typically test UNDER 0.01mm on well setup machines with no mechanical or electrical issues.

If you get a large range or standard deviation you should look for sources of movement in your Z-axis or the VREF on Z is set too low.

The motor couplers can contribute to the excess play and you can consider upgrading them to better ones (like Upgraded Couplers, TH3D sells them), ESPECIALLY if yours are stretched out. Failing that, contact our support for more troubleshooting. If the probe is bad we will replace it under warranty.